Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
BMC Pregnancy Childbirth ; 21(1): 359, 2021 May 05.
Artigo em Inglês | MEDLINE | ID: mdl-33952198

RESUMO

BACKGROUND: Diagnosis of preterm labour is difficult because initial symptoms and signs are often mild and may occur in continuing pregnancies. This study aims to investigate the utility of measuring cervical length, using transvaginal ultrasound, in women presenting to the delivery suite with symptoms of preterm labour. METHODS: This was a prospective cohort study performed in KK Women's and Children's Hospital, Singapore from September 2017 to July 2018. Women with singleton pregnancies, presenting with symptoms of contraction pain, between 24+ 0 to 36+ 6 weeks gestation, were included. Transvaginal ultrasound cervical length measurements were done at presentation to the labour ward, after four hours and in the following morning. The primary outcome of the study was delivery within 1 week. All statistical analyses were conducted with Microsoft Excel and Statistical Package for the Social Sciences. RESULTS: A total of 95 subjects were included. A one-millimeter increase in the 1st cervical length increases scan-to-delivery time by 0.802 days (p-value 0.003, CI 0.280-1.323). Receiver Operator Characteristic (ROC) curve analysis for prediction of delivery within 1 week showed an Area Under Curve (AUC) of 0.667, optimal cut-off value of 27.5mm (sensitivity 77.8 %, specificity 61.6 %). A one-millimetre increase in the 3rd cervical length increases scan-to-delivery time by 0.770 days (p-value 0.023, CI 0.108-1.432). ROC curve analysis for prediction of delivery within 1 week showed an AUC of 0.915, optimal cut-off value of 25.5mm (sensitivity 100 %, specificity 73.6 %). However, the change in cervical length over a period of 1 day was not significant in predicting delivery within 1 week. CONCLUSIONS: Our results indicate that by using a cervical length cut off of 27.5mm at presentation, we would have predicted 77.8 % of deliveries within 1 week. If we were to repeat the cervical length scan the next day, with the same cut-off of 27.5mm, we would have predicted 100 % of deliveries within 1 week. In our study, measuring the transvaginal ultrasound cervical length is a reliable diagnostic test for delivery within 1 week. However, the results are limited by the small sample size. Further studies should be conducted with a larger sample size.


Assuntos
Medida do Comprimento Cervical , Colo do Útero/anatomia & histologia , Início do Trabalho de Parto , Trabalho de Parto Prematuro/diagnóstico , Adulto , Colo do Útero/diagnóstico por imagem , Feminino , Humanos , Gravidez , Nascimento Prematuro , Estudos Prospectivos , Curva ROC , Fatores de Risco , Ultrassonografia Pré-Natal
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA